Part M requirements for offices
- Level or ramped entry (threshold ≤ 15mm)
- Minimum door widths — 800mm clear opening on main routes, 825mm on accessible routes
- Corridor widths — 1200mm minimum; 1800mm passing spaces
- At least one accessible WC per floor or group
- Accessible route to all amenity spaces
- Visual fire alarm supplementary to audible
- Induction loops at reception and meeting rooms
BS 8300 — going further
BS 8300 provides detailed best-practice dimensions. Not statutory, but referenced as 'deemed to satisfy' in many specifications.
Accessible WC specification
- 1500mm × 2200mm minimum cubicle
- Grab rails drop-down and fixed
- Transfer space 800mm from WC to side wall
- Alarm pull cord to floor + reset
- Emergency evacuation signage
- Colour-contrasted ironmongery and grab rails
- Lever taps, not quarter-turn
Common fit-out failures
- Door widths below 800mm clear
- Thresholds too high on meeting-room doors
- Reception desks lack low section (760mm high) for wheelchair users
- Accessible WC emergency alarm not tested
- Visual fire alarms omitted from breakout areas
What we do
Part M compliance integral to CAT B fit-out and WC refurbishment. See Commercial Washrooms, Office Fit-Out, Reception Refurbishment.
FAQs
Can we upgrade accessibility retrospectively?
Yes — most fit-out projects address historic non-compliance. Budget £8,000–£30,000 per WC core for upgrade.
Is Part M enforceable post-handover?
Enforceable at Building Control sign-off. Post-handover changes requiring building-control consent re-trigger compliance.