Commercial lighting and electrical services — LED upgrades, emergency lighting, small power distribution, data containment and BMS interface. NICEIC-certified installation with full EICR reporting.
Existing system survey and EICR
Lighting calculation (Relux / Dialux) to BCO/CIBSE standards
Design package — fittings schedule, small power layout, control strategy
Installation with NICEIC certification
Commissioning and EICR sign-off
| Tier | Range | What's covered |
|---|---|---|
| LED swap-out | £12–£22 per sqft | Like-for-like LED replacement of existing fluorescent |
| Full LED scheme | £24–£42 per sqft | New fittings, DALI control, emergency compliance |
| Premium / bespoke | £45–£95 per sqft | Architectural lighting, decorative pendants, feature lighting |
| Full electrical re-wire | £45–£85 per sqft | Distribution, small power, lighting, controls |
Figures are guide ranges — we provide a fixed quote after survey. City and Canary Wharf typically carry a 10–20% premium over outer zones.
Live-environment electrical works proceed under permit-to-work with trading-floor isolation slots booked with the occupier and managing agent. Main tests and commissioning typically require overnight isolation; final certification is issued within 24 hours.
Anonymised project outlines — full reference list with contact introductions available on request under NDA.
Scope · 28,000 sqft
Budget band · £480k
Programme · 8 weeks nights
Full LED with DALI, 12-year ROI on Cat B wiring
Delivered under single-contractor D&B with CDM 2015 principal contractor duty. Full compliance pack at handover.
Scope · 9,200 sqft
Budget band · £260k
Programme · 5 weeks
Architectural lighting with Casambi wireless
Delivered under single-contractor D&B with CDM 2015 principal contractor duty. Full compliance pack at handover.
Scope · 15,000 sqft
Budget band · £85k
Programme · 3 weeks
BS 5266 upgrade across 4 floors
Delivered under single-contractor D&B with CDM 2015 principal contractor duty. Full compliance pack at handover.
Yes — LED swap-out using existing circuits is common where the existing wiring is sound (post-EICR). Typical ROI on energy savings is 2–4 years.
Yes — we install Tridonic, Lutron, Casambi and Helvar systems, with commissioning and training for the FM team.
Yes — lighting is typically the largest single electrical load in an office. An LED upgrade with controls can lift an EPC from D/E into B/C territory.
Yes — annual full-duration discharge testing and monthly flick tests are offered under a PPM contract. Certificates to BS 5266 provided.
Area hubs with estate approvals, managing-agent compliance packs and loading protocols held on file. Four live now — remaining six launch in coming weeks.
In-depth articles on commercial fit-out, compliance and market strategy.
Measured condition survey within 5 working days. Fixed-price quote within 10. No open-book markup.